High Temperature Absolute Humidity Sensor for Humidity Measurement
The MAC 125 Moisture Analyzer is different from other comparable products in that it uses no chemicals, compressed air, wet bulb techniques, optics or mirrors. Instead, its moisture sensor and humidity meter relies on a patented, proprietary solid state humidity measurement process. This product incorporates a humidity sensor that provides a humidity reading based on the partial pressure of water vapor. The probe is protected from particles by a 10-micron ceramic filter element that is cleanable and replaceable.
What this means to you as a user is that you get the most accurate readings even in the most difficult, high-temperature operating environments. This moisture sensor gives users access to an original, innovate method of absolute humidity measurement. This makes it easier for you to improve your moisture control strategy.
Both the sensor and humidity meter have been designed to be exceedingly service-friendly. The moisture/humidity sensor is capable of giving precise readings at nearly any process temperature range.
MAC 125 Overview
- The MAC125 is the latest, and most advanced variety of Absolute Humidity Meters from MAC Instruments. The MAC125 humidity sensor and its predecessors have produced the trusted Humidity Sensors across the globe since 1990. Accuracy and reliability in high temperature moisture measurement are the hallmarks of all our products.
- Aware of the installation and mounting difficulties associated with competitors’ products, MAC Instruments has made a concerted effort to provide our moisture sensor with a no-fuss mounting capability. It can be mounted in a matter of minutes to stacks, ducts, flues, ovens, furnaces, calciners, kilns, dryers, fuel cells, etc.
- An easy-to-read humidity display meter is another highlight of the product. All important figures can be noted at a glance. MAC Instruments offers the MAC 125 in analog as well as digital models.
Here’s more on why the MAC 125 moisture sensor and humidity meter is a prudent investment:
- Measure Absolute Humidity to Virtually Any Temperature
- Measure moisture in a flame
- 2 Voltage Options
- 120V / 60Hz
- 230V / 50Hz
- Jumper Selectable Scales
- % Moisture by Volume
- Humidity ratio (lb water vapor / lb dry air) (g water vapor / g dry air)
- In-Situ Measurement
- Mounts directly to stacks, ducts, flues, ovens, furnaces, calciners, kilns, dryers, fuel cells, etc.
- NEMA 4X / IP53 Water Proof Design
- Suitable for outdoor installation
- Standard Signal Outputs (Jumper Selectable)
- 0-20mA ( 0 to 5V with 250 Ohm load )
- 4-20mA ( 1 to 5V with 250 Ohm load)
- Severe Duty Industrial Construction
- Stainless steel barrel
- Cast aluminum enclosure
- Automatic Altitude / Pressure Compensation
Model | % Moisture By Volume | Humidity Ratio |
---|---|---|
MAC125-100-120V | 0 to 100% | 0 to 10 |
MAC125-100-230V | ||
MAC125-60-120V | 0 to 60% | 0 to 1 |
MAC125-60-230V | ||
MAC125-30-120V | 0 to 30% | 0 to 0.25 |
MAC125-30-230V | ||
MAC125-20-120V | 0 to 20% | 0 to 0.15 |
MAC125-20-230V | ||
MAC125-10-120V | 0 to 10% | Not Available |
MAC125-10-230V |
Temperature Range
- 40° F / 4° C to 1200° F / 650° C – Above 1200° F requires special mounting tube
Pressure Range
- 1 Atmosphere ± 5 PSI / 35 kP
Accuracy
- ± 1% of %Mbv Full Scale
Repeatability
- ± 1 % of %Mbv Full Scale
Linearity
Http Analyzer For Mac Windows 10
![Http Analyzer For Mac Http Analyzer For Mac](https://vignette.wikia.nocookie.net/logopedia/images/f/f7/Publisher_2007_icon.png/revision/latest/scale-to-width-down/200?cb=20180424233934)
- ± 1 % of %Mbv Full Scale
Response Time
- 120 Seconds or less to reach 90% of final value
Analog Output
- ± 1 % of %Mbv Full Scale
Power Requirements
- 120V / 60 Hz or 230V / 50 Hz, 3A max (Specify required voltage when ordering)
Options
- Digital Display (Built into MAC125)
- Case Cool Soleniod valve (requires 10 PSI / 69 kPa Clean, Dry Air) for Operation at High Ambient Temperature
- Filter Blow Back Soleniod valve (requires 10 PSI / 69 kPa Clean, Dry Air) filter can be blown out by closing an external contact or by setting a time for the valve to open for 2 seconds daily (jumper selectable)
- Various Standard and Custom Mounting Tubes and Adapters
Find a Distributor
MAC 155 Humidity Probe & Humdity Transmitter For Continuous Stack Monitoring With Built in Two Point Calibration
The MAC 155 moisture/humidity analyzer enables you to augment your process safety and comply with US EPA regulations. Several high-quality components such as a humidity probe and humidity transmitter combine to make this device exceptionally user-friendly. MAC 155 is used in industrial operations worldwide for 24/7 monitoring of stack emission gases. It is designed for measuring humidity in exhaust gases in temperatures ranges up to 1200°F (650°C). MAC Instruments also provides a range of special accessories to expand the usability of the humidity probe in temperatures up to 2400°F (1300°C).
A defining attribute of the MAC 155 humidity transmitter is that it features an in-built calibration system. This makes daily 2-point in-situ calibration and system checks possible, and facilitates adherence to US EPA regulations and local mandates pertaining to exhaust stack installations. The humidity probe is protected from particles by a 10 micron stainless steel sintered filter element that can be easily cleaned and replaced.
The humidity probe on this unit is exceedingly sensitive to water vapor/humidity. However, it does not rely on a wet bulb, mirrors, optics, chemicals, or compressed air to provide readings. This humidity meter is highly responsive to the partial pressure of water vapor, thus displaying instantaneous readings. You can confidently depend on MAC Instrument’s patented solid state design to help you improve overall process efficiencies in the toughest industrial settings. The MAC 155 humidity transmitter is available in two models for low range and high range continuous humidity monitoring.
- MAC-155 Humidity Analyzers is Avilable in Two Models:
- MAC155-LT covers 3% to 15% or 6% to 30% ranges (user selectable)
- MAC155-HT covers 3% to 15%, 6% to 30%, 9% to 45%, or 12 % to 60% ranges (user selectable)
Message Analyzer Https
- Features of the MAC-155 Moisture/Humidity Transmitter
- Measure % Moisture By Volume In Exhaust Gasses At Temperatures up to 1200°F
- Optional to 2400°F
- NEMA 4X Waterproof Design
- Suitable for outdoor installation
- Contains Built In Equipment Allowing Daily 2 Point Calibration Check
- Sensor is flooded with an internally generated reference gas of specific himidity levels
- Can Be Re-Calibrated In the Field Using Internal Calibrator
- System Calibration
- Sensor signal substitution can be externally initiated to generate an ouput signal 50% of full output.
- From the MAC155 Controller, 3 different output signals can be generated.
- Provides a method of checking total system includingdata aquisition equipment.
- Patented Measurement Process
- In Situ Measurement
- Mounts directly to stacks or ducts
- 0-20mA or 4-20mA Signal Output User selectable Self powered or loop powered (jumper selectable)
- Filter Blow Back Option
- Allows automatic filter cleaning (requires 10 psi clean dry air)
- Case Heater Option
- Extend ambient temperature rating to -40°F
Http Analyzer For Mac Download
The Standard For High Temperature Humidity Measurement
- The MAC 155 In Situ Moisture Analyzer is designed to continuously monitor emission stack gases.
- It is designed to meet EPA and local regulatory requirements for stack gas moisture/humidity measurements.
- The patented solid state design has been proven in hundreds of industrial process control applications.
- The moisture sensor is extremely rugged and requires no chemicals, compressed air, optics or mirrors.
- The % moisture by volume is measured using a proprietary high temperature capacitive sensor that responds to water vapor pressure in the presence of other gasses.
- The MAC155 Moisture Analyzer used as Humidity Transmitter is provided with automatic two point calibration check at user selectable humidity levels. The on board calibration system can challenge the sensor with a controlled water vapor sample. An internal tank holds enough water to generate vapor samples for one year of daily calibration checks.
Specifications
Pc System Analyzer
- Measurement Range
- (MAC155-LT)
- 3% to 15% or 6% to 30% water vapor by volume (user selectable)
- (MAC155-HT)
- 3% to 32%, 6% to 30%, 9% to 45%, or 12% to 60% water vapor by volume (user selectable)
- (MAC155-LT)
- Maximum Stack Gas Temperature
- 1200°F (optional to 2400°F)
- Ambient Temperature Range
- 30°F to 140°F (-40°F with case heater option)
- Altitude Range
- sea level to 6000 feet
- Accuracy
- ±1% of full scale
- Linearity
- ±1% of full scale
- Response Time
- 60 seconds or less to reach 90% of final value
- Analog Output
- 0-20mA or 4-20mA. Internal powered
- Power Requirements
- 120V 60HZ @ 3A max
Calibration System
Http Analyzer For Mac Shortcut
- Calibration Check Points
- (MAC155-LT)
- 6% and 12% or 12% and 24%
- (MAC155-HT)
- 6% and 12% or 12% and 24% 0r 18% and 36% or 2[4% and 48%
- (MAC155-LT)
- Calibration Point Accuracy
- 0.5% of full scale
- Distilled Water Tank Capacity
- 26 oz. (22 oz. usable)
- Water Usage
- 20 oz. per year